frawanjo@techmepi.com +254 723 509 854 Buruburu Business Complex, 2nd Floor Room 22, Nairobi, Kenya
Mon–Fri 8:00–17:00

Implementation

Engineering & Delivery

Site supervision, installation coordination, testing, commissioning and disciplined project delivery through to documented handover.

Service Overview

What we deliver

A coordinated design creates value only when the installation on site matches it. TechMEPi manages that transition from approved information to working systems through active supervision, trade coordination, quality control, testing and commissioning.

Implementation begins before mobilisation. We review shop drawings, method statements, material submittals, procurement status and builders' work requirements, then agree inspection and test points with the delivery team. This puts the quality standard and sequence in writing before work is concealed or equipment arrives late.

During installation

  • Site supervision and workmanship inspections
  • MEP trade, structure and architecture interface coordination
  • Shop drawing, material and method-statement reviews
  • Progress measurement and short-term work planning
  • Snag, non-conformance and corrective-action tracking
  • Contractor queries and design clarification
  • Photographic records and installation status reporting

Testing and commissioning

Systems are not accepted because they switch on. We review the commissioning plan, witness pressure and leakage tests, verify electrical and controls interfaces, check balancing and operating set-points, and compare results with the approved design criteria. Defects are recorded and retested to closure, with evidence retained in the handover pack.

Handover

Completion includes coordinated as-built drawings, equipment schedules, test certificates, commissioning records, O&M manuals, warranties, spares and operator training. We track these alongside physical works so the client receives an operable asset and a usable technical record, not a box of incomplete documents after occupation.

Flexible engagement

TechMEPi can implement its own designs, supervise a contractor under an independent consultancy appointment, or provide targeted commissioning and close-out support. In every arrangement, authority, inspection frequency and acceptance responsibilities are defined before work starts.

What’s included

  • Pre-mobilisation and constructability reviews
  • Site supervision and trade coordination
  • Submittal and method-statement reviews
  • Quality inspections and snag control
  • Testing and commissioning plans
  • Witnessed performance verification
  • As-built, O&M and handover coordination

From our installations

TechMEPi mechanical plant room building-services installation
Commissioned chilled-water plant room with labelled distribution pipework and buffer vessels
System Schematic

Our delivery workflow — design to handover

01 Design & Engineering Revit · AutoCAD
02 Coordination BIM · clash · hydraulics
03 Installation Supervised on site
04 Commissioning Tested & balanced
05 Handover As-built + O&M

Engineering Drawings & Schematics

See the drawings before you commit

Every discipline is issued as a proper drawing sheet — title block, revision history, legend, general notes and calculated sizes. These are illustrative samples drawn on a neutral reference building, watermarked and marked not for construction, so client schemes stay confidential.

BIM Coordination

BIM Services Coordination

Building section · riser shaft and ceiling-void zoning

DWG TMEP-BIM-DWG-601 REV C1 SCALE 1:100 @ A3
BIM Coordination

Plant Room Coordinated Layout

Plan & section · clearances and service zoning

DWG TMEP-BIM-DWG-621 REV C1 SCALE 1:50 @ A3
Typical Details

Typical Installation Details

Supports · fire-stopping · chambers · access · isolation

DWG TMEP-STD-DWG-901 REV C2 SCALE AS NOTED @ A3
FAQ

Common Questions

Can TechMEPi supervise an installation by another contractor?

Yes. We can act as the client's independent engineering representative, reviewing submittals, inspecting work, witnessing tests and reporting compliance against the approved design and specification. Our authority and inspection schedule are agreed in the appointment.

What must be complete before commissioning starts?

The installation must be mechanically and electrically complete, pre-commissioning checks closed, utilities and controls available, instruments calibrated and test procedures approved. Starting earlier usually produces unreliable results and repeated tests, so readiness is verified system by system.

What is included in a proper handover package?

At minimum: accepted as-built drawings, equipment and asset schedules, test and commissioning records, O&M manuals, warranties, statutory certificates, spares lists and operator training records. The exact register is agreed early and tracked to closure.

Explore More

Related Services

Project Management

PMP-led planning, coordination, procurement, scheduling, cost, quality and stakeholder management for technica...

Details